High frequency tilt control : -2dB / Flat / +2dB (@ 10kHz)
Room control : Flat / -2dB / -4dB (@ 100Hz)
Base cut-off frequency control : Flat / 80Hz(THX) / 100Hz (-12dB/octave)
Acoustic System Compensation rage : 30Hz ~ 200Hz, +/-6dB Max
Indicator: power/protection (front, white LED)
AC Power Input :
- Max rated power : 115 watts
- 100 ~ 120VAC, 200 ~ 240VAC, 50~60Hz via IEC power INLET
5.2. DA-912
Connector: XLR input (AES/EBU, IEC60958), RCA input (S/PDIF, EIAJ CP1201), RCA thru output
Sample Rates: 192kHz, 176.4kHz, 96k Hz, 88.2 kHz, 48 kHz, 44.1 kHz, 32 kHz. Tolerance: +/- 3%
Word Length: 16-24 Bit
Digital Analog Converter: 24-bit/192kHz Multi-bit delta-sigma with 8xdigital filter
Total Harmonic distortion + Noise : 0.0005% (@1kHz, -3dBFS)
Dynamic range : 123dB A-weighted, (@1kHz, -60dBFS)
User interface : Input source selector (AES/EBU/Coaxial), Channel selection (Left/Right), Status
indicator LED